Basal ganglia bleed

Case contributed by A.Prof Frank Gaillard
CT

Axial non contrast CT image demonstrates a hyperdense focus centered on the globus pallidus on the left with a faint rim of low attenuation. Findings are characteristic of a basal ganglia hemorrhage

MRI

MRI a few days later

MRI obtained a few days later variable signal consistent with the subacute timing. The majority of the bleed demonstrates high T1 and T2 signal consistent with extracellular met-Hb, with a peripheral rim of low signal (best seen on gradient echo) representing hemosiderin. 

Time of flight MRA demonstrates the bleed as a globular region of high signal which should not be misinterpreted as flow.*  

* As time of flight (TOF) MRA is a T1 weighted sequence relying on pre-saturation of non-moving tissue, very intense T1 signal material will still be visible (as seen here with the clot). This also makes TOF a poor choice for MRV as clot will appear bright and may be mistaken for flow.

Case Discussion

Spontaneous basal ganglia bleed in a known hypertensive. CT performed on the day of presentation. MRI a few days later.

 

PlayAdd to Share

Case information

rID: 2764
Published: 22nd May 2008
Last edited: 13th Aug 2019
Tag: stroke
Inclusion in quiz mode: Included

Updating… Please wait.